Logo Enrico Bruno srl
The items you find are only part of our catalog. We are in the process of completing the insertion

Code HI656321

Benchtop conductivity meter with advanced features HI 6321

Conductivity/Resistivity/TDS/Salinity meter

The HI6321 is an advanced benchtop meter designed for professional Conductivity/Resistivity/TDS/Salinity measurement.

Featuring a large, intuitive touchscreen and innovative features, this device is perfect for a wide range of applications from potable water to industrial process water.

The included HI7631233 four-ring probe provides stable measurements over a wide range and requires infrequent calibration.

With its built-in temperature sensor, the HI6321 provides accurate analysis with automatic temperature compensation, making it essential for precise water quality assessment.
  • Advanced Touchscreen Interface
  • Multiple Scales of Measurement
  • Internet connection

Temperature sensor

The integrated temperature sensor measures the sample temperature and allows automatic compensation during analysis, with the possibility of choosing the type of algorithm to apply:

  • Linear : appropriate when the temperature coefficient of variation is assumed to have the same value for all measured temperatures

  • Standard : Suitable for high purity water analysis and documented in ASTM D5391-14. This setting should be used for resistivity measurements >1Mohm.cm.

  • Natural : Suitable for natural groundwater, well or surface water (or water with similar composition) according to ISO7888 standard.

The result is a reliable analysis of conductivity (EC), TDS (Total Dissolved Solids), resistivity or salinity of seawater (percentage units, PSU or ppt).

TDS Factor

TDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.

Salinity expressed in PSU (Practical Salinity Unit)

Practical salinity of seawater relates the electrical conductivity ratio of a normal seawater sample at 15 °C and 1 atmosphere to a potassium chloride (KCl) solution with a mass of 32.4356 g/kg of water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. Practical salinity scale can be applied to values ​​from 0 to 42.00 PSU at temperatures between 0 and 35 °C.

Salinity expressed in ppt

Measurements expressed in ppt are based on the natural seawater scale which ranges from 0.00 to 80.00 g/L and covers a temperature range of 10 to 31 °C. Determine salinity based on a ratio of the sample conductivity to standard seawater at 15 °C and an approximate salinity value of 35 in seawater.

Salinity expressed in %

On this scale, 100% salinity equals approximately 10% solids.

Detailed Specifications

Measurement

  • Measurement scales: μS/cm, mS/cm (Conductivity); Ω cm, kΩ cm, MΩ cm (Resistivity); ppm, ppt (TDS); ppt, PSU, % (Salinity) and temperature
  • Recording function active during measurements
  • Measurement stability indicator (using the Stability Criteria setting)
  • Reading Mode: Direct and Direct with Autohold
  • Automatic temperature compensation (via temperature probe) or manually set
  • Acoustic and/or alarm messages for measurements outside the predefined limits
  • Galvanically isolated probe input to avoid electrical interference during measurements
ParametroDescrizione
EC Scala 0.000-9.999 μS/cm; 10.00-99.99 μS/cm; 100.0-999.9 μS/cm;   1.000-9.999 mS/cm; 10.00-99.99 mS/cm; 100.0-1000.0 mS/cm
Risoluzione 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm;   0.1 mS/cm
Accuratezza ±1 % of reading (±0.01 μS/cm)
Resistività Scala 1.0-99.9 Ω·cm; 100-999 Ω·cm; 1.00-9.99 KΩ·cm; 10.0-99.9 KΩ·cm;   100-999 KΩ·cm; 1.00-9.99 MΩ·cm; 10.0-100.0 MΩ·cm
Risoluzione 0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm;   0.1 MΩ·cm
Accuratezza ±1 % of reading (±1 Ω·cm)
Solidi Totali   Disciolti (TDS) Scala 0.000-9.999 ppm; 10.00-99.99 ppm; 100.0-999.9 ppm; 1.000-9.999   ppt; 10.00-99.99 ppt; 100.0-400.0 ppt; actual TDS (with 1.00 factor)
Risoluzione 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Accuratezza ±1 % of reading (±0.01 ppm)
Salinità Scala 0.00-42.00 PSU - Practical Scale; 0.00-80.00 ppt - Natural Sea   Water; 0.0-400.0 % - Percent Scale
Risoluzione 0.01 for Practical Scale / Natural Sea Water; 0.1 % for   Percent Scale
Accuratezza ±1 % della lettura
Temperatura Scala −20.0-120.0 °C
Risoluzione 0.1 °C
Accuratezza ±0.2 °C
Calibrazione EC Punti di calibrazione Riconoscimento automatico dei tamponi / valori impostabili   dall'utente, singolo punti /più punti
Soluzioni 84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00   mS/cm, 111.8 mS/cm
Avviso Disabilitato; Giornaliero: 0 min. fino 23 ore e 59 min;   Periodico: 1 min. a 500 days, 23 ore e 59 min.
Calibrazione Resistività Come Conducibilità
Calibrazione Salinità 1 punto per scala percentuale
Compensazione Temperatura Automatica o Manuale
Lettura Modalità Diretta; Diretta/Autohold
Stabilità Accurato; Medio; Veloce
Frequenza di campionamento 1000 ms
Visualizzazioni Base Misurazione (EC, Resistività, TDS, Salinità, Temperatura); Stato di   stabilità
GLP semplice Informazioni di base; Ultima data di calibrazione, offset
GLP completa Informazioni GLP Semplici e dettagli del punto di calibrazione
Tabella Le misurazioni aggiornate ogni secondo vengono visualizzate in tabella
Grafico l grafico della misurazione nel tempo può essere spostato o ingrandito   (tecnologia pinch-to-zoom)
Registrazione dati Tipo Automatica, Manuale, Autohold
Numero di record Massimo 50.000 per file; Memorizza almeno 1.000.000 di punti dati per   utente
Intervallo automatico 1, 2, 5, 10, 30 secondi; 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minuti
ID campione Incrementale
Formato esportazione .csv file
Utenti Fino a 9 utenti e l'account amministratore   predefinito
Connettività USB-A 2 porte per l'inserimento della tastiera o chiavetta USB
USB-C 1 porta per la connettività al PC e chiavetta USB-C
Wi-Fi & Ethernet FTP; Server web per trasferimento e download dei log; Email
RS232 Collegamento per periferiche
Alimentazione Adattatore DC 100-240AC a 24VDC 2.5A
Condizioni di utilizzo 0 - 50 °C    massimo 95% RH senza condensa
Dimensioni 205 x 160 x 77 mm
Peso Circa 1.2 kg

CONTACTS


ENRICO BRUNO s.r.l.
Via Duino 140
10127 Torino Italy
Tel. +39 011 3160808
Fax +39 011 3160753
PEC pec@pec.enrico-bruno.it
CF/P.IVA: 04891320014

WRITE TO US


For orders, prices requests and offers, technical service commerciale@enrico-bruno.it
For administration service amministrazione@enrico-bruno.it
For Direction – Purchase Department acquisti@enrico-bruno.it

FOLLOW US


Facebook Twitter Blogger